Skip to main content

300x250 Ads

Display-Devices-Recorders

 Introduction
 
The last stage of instrumentation & measurement is display devices & recorders. Because the results of a measurement system are meaningful, they must be displayed for instant observation of for storage for observation at a later stage. The first device is called a “display device” and the second a “recorder”. The data presentation devices may be called as output devices.



 Advantage of digital display system

 

Faster
Lighter weight
Cheap
Low error probability
Compatible with other devices
Adjustable resolution gives better display
Low power consumption
 Our Focus

Seven segment display
Liquid crystal display
Cathode ray tube
Digital Frequency Meter
Digital Voltmeter (DVM)

                          seven-segment display (SSD)


A seven-segment display (SSD), or seven-segment indicator, is a form of electronic display device for displaying decimal numerals that is an alternative to the more complex dot-matrix displays. Seven-segment displays are widely used in digital clocks, electronic meters, and other electronic devices for displaying numerical information.
The idea of the seven-segment display is quite old. In 1910, for example, a seven-segment display illuminated by incandescent bulbs was used on a power-plant boiler room signal panel.

 


 

Download the ppt file

Comments

Popular posts from this blog

Armature Winding ,Pole Pitch, Coil Span, Commutator Pitch

Now we are going to discuss about armature winding in details. Before going through this section, we should understand some basic terms related to armature winding of dc generator . Pole Pitch Definition of Pole Pitch The pole pitch is defined as peripheral distance between center of two adjacent poles in dc machine. This distance is measured in term of armature slots or armature conductor come between two adjacent pole centers. This is naturally equal to the total number of armature slots divided by number of poles in the machine. If there are 96 slots on the armature periphery and 4 numbers of poles in the machine, the numbers of armature slots come between two adjacent poles centers would be 96/4 = 24. Hence, the pole pitch of that dc machine would be 24. As it is seen that, pole pitch is equal to total numbers of armature slots divided by total numbers of poles, this can alternatively referred as armature slots per pole . Coil Span or Coil Pitch Coil of ...

Propagation-Radio-Waves

Radio Wave Propagation types

Winding Factor | Pitch Factor | Distribution Factor

Before knowing about, winding factor , we should know about pitch factor and distribution factor , as winding factor is the product of pitch factor and distribution factor . If winding factor is denoted by K w , pitch factor and distribution factor are denoted by K p and K d respectively, then, k w = k p k d . The pitch factor and distribution factor are explained below one by one.   Pitch Factor In short pitched coil, the induced emf of two coil sides is vectorically added to get, resultant emf of the coil. In short pitched coil, the phase angle between the emfs induced in two opposite coil sides is less than 180° (electrical). But we known that, in full pitched coil, the phase angle between the emfs induced in two coil sides is exactly 180° (electrical). Hence, the resultant emf of a full pitched coil is just arithmetic sum of the emfs induced in both sides of the coil. We well know that, vector sum or phasor sum of two quantities, is always less than their a...

Add